Service status

All good: all 15 services are working.

APN Authentication Outage

ResolvedDegraded

Times are shown in UTC

Affected
BT, GLOBAL, Telefónica, Vodafone GDSP, Vodafone UK, APN infrastructure
Started
How long
Lasted 17 days

Updates

  1. Resolved

    ### Root Cause Analysis (RCA) Within the database clusters that inform the APN which device has which IP, a procedure which logs the allocation history for various troubleshooting applications ( DNS, SMTP & DataFlow) was causing a record lock. This procedure was modified in August 2023. Under certain circumstances the record lock caused the querying RADIUS server to timeout and failover to an alternative database, which then caused another record lock and timeout, until all RADIUS servers were locked out of all databases. The procedure was redesigned to substantially reduce disk IO operations and no more record lock issues have been identified. However, engineers continued to investigate the platform with the RADIUS vendor and identified database access timeouts within the RADIUS servers that can be extended to avoid timeouts. These have been modified to remove the risk total failover collapse. Having identified the database procedure and the RADIUS timeouts as causal, tests recreating the conditions have been performed and the platform does not repeat the issue and failover occurs gracefully in all circumstances. Moving forward to remove the requirement for all device/IP mapping logs, we will be implementing local fixed IP for all devices, even when using the default dynamic IP firewall service. This uses the new automated Fixed IP allocation service rolled out Q1 2022 in preparation for customer self service. This change will mean that the RADIUS platform will use read only databases substantially reducing complexity and management. This project will take 6 months to complete and will not affect any devices as they transition to new IP ranges with fixed IP addresses. There will be no notifications of this change, but devices on the portal and other reports will show an IP address in all circumstances.

  2. Monitoring

    The APN authentication platform failed, but the automated restart ensured less than 1 minute of downtime. Logs are being analysed by engineers to identify the root cause.

  3. Monitoring

    Various logging functions have been added across the APN authentication platform to identify the root cause of the authentication platform failures. In addition an automated reset trigger for the platform has been implemented should the exact problem re-occur.

  4. Monitoring

    The APN service has been reset and has resumed service. Engineers continue to investigate the root cause.

  5. Monitoring

    Issues with the APN platform have returned, engineers are investigating.

  6. Monitoring

    Engineers are monitoring the APN platform as the root cause of the issue has not been identified.

  7. Identified

    The APN service has been reset and traffic has resumed.

  8. Investigating

    Devices using the datasim.com, datasim.global, global, roaming & nb.datasim.com APNs are experiencing issues with authenticating and being granted data access. Engineers are investigating.