IP-Data Outage Affecting Telefonica IoT Services
ResolvedDegraded
Times are shown in UTC
- Affected
- Telefónica
- Started
- How long
- Lasted 45 days
Updates
- Resolved
Root Cause Analysis * The Initial Problem: CISCO routers and CISCO firewalls providing data transit into the DataSIM network exhibited connectivity drops following a platform rebuild by Telefonica on the 29th November. These drops usually lasted a few minutes, but on rare occasion spanned hours and either self resolved or required a reset of the applications. The events occurred 10 times per week on average, reducing uptime to 99.4%. * The Initial Response: It was assumed that the cause was a Telefonica configuration issue, resulting from the rebuild. Telefonica engineers made changes to the settings over several weeks of testing and soak testing without improvement. The entire configuration was then rebuilt, this resulted in an improvement in service and so engineers continued looking for configuration issues through the network. Eventually, the only action that had not been taken was to ensure the routers and firewalls were of the same product family in case of incompatibility, so this was implemented. * The Resolution: Changing the firewall to the same product family as the routers resulted in return to 100% uptime. This would indicate that compatibility was an issue. On investigation however there are no compatibility issues with other networks with the same software versions, or indeed within Telefonica prior to the 29th November. So it is not possible to confirm it as the actual cause, but only as the likely cause as a matter of logic. * Changes In Procedures Moving Forward: In the event of issues within the same context, moving traffic to devices of the same product family will be considered within the initial response.
- Resolved
Connectivity has operated at 100% uptime since the change on Monday last week. The issue has been marked as resolved. A Root Cause Analysis is in progress.
- Monitoring
Switch over to the new configuration completed without issue. Close monitoring of the service will continue for the next 7 days.
- Monitoring
The service configuration implemented on Thursday last week has not met the minimum service level criteria and will be replaced with the CISCO same family configuration built on Friday. This new configuration has been stable since implementation. Live traffic will be switched over between 12:00 UTC and 13:00 UTC today. Data connectivity is expected to drop for a few minutes. Devices will not lose data sessions and will not need to re-authenticate to the network or APN.
- Monitoring
Work is ongoing between DataSIM and Telefonica to resolve the root cause of intermittent drops in data connectivity. These drops typically last between 2 to 5 minutes and occur once or twice per day. The root cause is believed to be an undocumented incompatibility between CISCO appliances within the network. Yesterday, on the 11th January, the service configuration was updated and reloaded. We are monitoring the impact of this change, so far connectivity has been stable. In case this does not resolve the issue a new networking solution is being built that ensures all CISCO routers have the maximum compatibility. This will be implemented today and tested over the weekend. A technical review will occur on Monday and if necessary all traffic will be moved to the new solution Monday at 13:00 UTC. Implementation of this solution is not expected to result in longer than a data drop of longer than one minute.
- Identified
Telefonica have prepared a new configuration for a failing service on the network, with an implementation window of 2023-12-21 12:00 UTC-Z and 2023-12-21 14:00 UTC-Z tomorrow. IP-Data connectivity will stop and start with a total down time of up to 1 minute during the implementation window. Devices will not need to re-register to the mobile network, or re-authenticate to the APN. This is a low risk event.
- Identified
Telefonica engineers working with DataSIM technicians have identified an issue within the Telefonica network following their platform wide outage on 2023-11-30. It is not yet known if this is the root cause of the current intermittent connectivity failure. Telefonica made a change at 12:15 UTC today which corrected this specific issue. The network is being monitored 24x7 by DataSIM and Telefonica.
- Investigating
Telefonica IoT data service metrics are showing degradation using IP data only.